 Features
System BusPCI (32-bit, universal keyed)
Data Rate per Port, Max.460.8 kbps
Number of RS-232/422/485/530 Serial Ports1
 
Introduction

COML 106U-D25 is a one-channel 5V/3.3V PCI bus serial communications card. It comes with a 16850 UART, which provides deep 128-byte FIFO buffers and makes programming easy because it emulates the more common 16550 UART.

COML 106U-X-D25 is similar, but it comes with a 16C950 UART, which adds isochronous communication, 9-bit protocols, and programmable choice of transmission speed. We recommend it for savvy programmers.

The cards ship have standard-height backplates, but for smaller chassis they also ship with low-profile backplates (only 8cm high).

  Less Detail  More Detail
Product Information
System Bus PCI (32-bit, universal keyed)
Interface Standards Compliance PCI 2.2
PCI MD1
Data Rate per Port, Max. 460.8 kbps
Data Rate per Port, Max. (simul. on all channels) 460.8 kbps
FIFO Buffer Length 128 Bytes
Card Backplate Standard (12cm) backplate
Low-profile (8cm) backplate
Mounting Configuration Internal card
I/O Ports
Serial Ports UART/Controller Type 16C950
Function Type DTE device
Number of RS-232/422/485/530 Serial Ports 1
Serial Port Mode Select Jumper-selectable
RS-232 Signals Supported TXD (TD, TX) Transmitted Data
RXD (RD, RX) Received Data
RTS : Request to Send
CTS : Clear to Send
DCD (CD) Data Carrier Detect
DSR : Data Set Ready
DTR : Data Terminal Ready
RI : Ring Indicator
GND : Signal Ground
TXC : Transmit Clock
RXC : Receive Clock
TSET : Transmit Signal Element Timing
RS-422 Signals Supported GND : Signal Ground
TD+ (TX+) Transmit Data +
TD- (TX-) Transmit Data -
RD+ (RX+) Receive Data +
RD- (RX-) Receive Data -
RTS+ : Request to Send
RTS- : Request to Send
CTS+ : Clear to Send
CTS- : Clear to Send
TXC+ : Transmit Clock +
TXC- : Transmit Clock -
RXC+ : Receive Clock +
RXC- : Receive Clock -
TSET+ : Transmit Signal Element Timing +
TSET- : Transmit Signal Element Timing -
RS-485 Signals Supported GND : Signal Ground
TD+ (TX+) Transmit Data +
TD- (TX-) Transmit Data -
RD+ (RX+) Receive Data +
RD- (RX-) Receive Data -
RTS+ : Request to Send
RTS- : Request to Send
CTS+ : Clear to Send
CTS- : Clear to Send
TXC+ : Transmit Clock +
TXC- : Transmit Clock -
RXC+ : Receive Clock +
RXC- : Receive Clock -
TSET+ : Transmit Signal Element Timing +
TSET- : Transmit Signal Element Timing -
EIA-530/RS-530 Signals Supported GND : Signal Ground
TD+ (TX+) Transmit Data +
TD- (TX-) Transmit Data -
RD+ (RX+) Receive Data +
RD- (RX-) Receive Data -
RTS+ : Request to Send
RTS- : Request to Send
CTS+ : Clear to Send
CTS- : Clear to Send
TXC+ : Transmit Clock +
TXC- : Transmit Clock -
RXC+ : Receive Clock +
RXC- : Receive Clock -
TSET+ : Transmit Signal Element Timing +
TSET- : Transmit Signal Element Timing -
DCD+ : Data Carrier Detect +
DCD- : Data Carrier Detect -
DTR+ : Data Terminal Ready +
DTR- : Data Terminal Ready -
DSR+ : Data Set Ready +
DSR- : Data Set Ready -
Connector(s) Number of Connectors 1
Connector Type DB-25 (25-pin)
Connector Gender Male (pin)
Connector Pinout Standard EIA-530 / RS-530
Power
Power Consumption 480mA @ +5V; 50mA @ +12V; 50mA @ -12V
Software
Operating System(s) Supported Windows XP
Windows NT
Windows 2000
Windows Me
Windows 98
Windows 95
Windows NT 4
Windows 98SE
Software Included Free Windows® advanced COM: drivers, utilites, INF files and help files to simplify installation
Environmental Specifications
Operating Temperature 32°F....122°F (0°C....50°C)
Storage Temperature -4°F....158°F (-20°C....70°C)
Relative Humidity, noncondensing 10%....90%
Safety & Standards Compliance
Safety/Approvals Meets FCC Part 15 - Class A EMI specs
Meets EMC Directive 89/336/EEC
Meets TUV IEC 950 specs
Meets CE Class A
Meets EMC Directive 73/23/EEC
Meets UL 94V0 standards
MTBF (average) 150000 hours
Dimensions
Card Length 4.27" (108.48mm)
Card Height 2.54" (64.41mm)
Less Detail Less Detail
 
Ordering - Includes Options Indicated Below
COML 106U-D25
PCI 1-Port RS-232/422/485/530 Serial Interface Card, 460.0 kbps Data Rate, 128-Byte FIFO Buffer, with DB-25M Connector
$169.00
COML 106U-X-D25
PCI 1-Port RS-232/422/485/530 Serial Interface Card, 460.0 kbps Data Rate, 128-Byte FIFO Buffer, with DB-25M Connector and Isochronous Communications
$219.00
Catalog # Shipping Price (with options) Qty  
COML 106U-X-D25 1-2 weeks
Customers Were Also Interested In These
COU 204C $115.00
Type II CardBus (PCMCIA) 4-Port CardBus PC Card, 480Mbps Data Rate, with 4 USB Ports and DC Power Supply
CBL 2503MF $15.00
25-Pin Round Shielded Cable, DB-25 M-F, 3 ft
CBL 2506MF $18.00
25-Pin Round Shielded Cable, DB-25 M-F, 6 ft
Did you find this page useful?
Toll-Free Hotline 1-800-341-2525 • Tel: 203-483-8815 • Fax: 203-483-9024
©Copyright 2010 , CyberResearch Inc., Branford, CT USA All Rights Reserved