CyberResearch Home 1-800-341-2525 HomeProductsLive HelpPrintClose Window
Home  Data Acquisition & Control Systems  Terminal Panels / Breakout Panels  Analog Signal Conditioning
32-Channel Multiplexing Panel
32-Channel Multiplexing Panel
CYEXP 32

32-Channel Analog Input Multiplexing Panel (32 inputs to 2 outputs)

Qty   Price (with options selected)
Shipping: Call for Availability
 Features
Number of Channels32
Number of Analog Output (D/A) Channels2
Number of I/O Lines4
 
Introduction

The CYEXP 16 is a signal conditioning accessory board that expands the number of analog inputs and the range of amplification of the CYDAS 8, 800, 1200, 1600 and CYDAS 16 family of boards. Used with an 8-channel A/D board, CYEXP panels can be daisy-chained to provide up to 128 inputs. Your A/D board selects the CYEXP input to be read using 4 digital output lines.

The CYEXP 16 has 16 inputs in one bank, which is connected to a jumper block labeled "EXP Output to DAS." The bank of 16 inputs is multiplexed to one output channel. This output from the CYEXP 16 is connected to one analog input of the A/D board in your computer. The analog input channel on your A/D board must be single-ended to be compatible with the CYEXP. The CYEXP 32 is two CYEXP 16s on one panel, multiplexing 32 differential input channels onto two single-ended A/D channels on your DAS board

An on-board Cold Junction Compensation (CJC) sensor can be mapped to an unused A/D channel to increase the accuracy of thermocouple readings if some of your signals are from thermocouples.

The CYEXP 16L and CYEXP 32L are the same as the regular CYEXP boards, but they use lift-off terminal strips. This is useful for data acquisition systems that must be shared between applications.

Input gain is selected for each bank of 16 channels. The on-board gain amplifier can provide gains of 1, 10, 100, 200, and 500. These gains are selected via a DIP switch, and are additive - by setting both the 500 and the 200 switch ON, you achieve a gain of 700. Gain range should be set to provide an output in the ±5V (preferred) to ±10V (max) range. As this is an analog-to-analog panel, the output range is directly related to the input signal and the gain setting. Of course, if no gain is selected, signals are passed straight through without amplification (gain=1).

The CYEXP family also features 8-channel RTD and bridge, 16-channel RTD, or bridge completion multiplexing panels.

Note: Our CYEXP 32L-5PK is special order, for a pack of five multiplexing panels. (If you need more than five, please call.) Leadtime approximately 8 weeks. Sorry, no returns on this item.

  Less Detail  More Detail
Product Information
Designed to Replace Keithley Metrabyte EXP-32
Mounting Configuration Desktop / benchtop
Rack-mount (with optional kit)
Analog Input Channels
Number of Channels 32
Differential Channels 32
Cold Junction Compensation Independent input channel for CJC
Input Impedance 100MΩ
Input Impedance Details From the factory, impedance is >100 megohms minimum. If you short the "V" and "G" pads on the board for thermocouple support, the input impedance becomes 100kohms, minimum.
Input Protection Protected against voltages to +/-20VDC, max. with power off
Protected against voltages to +/-35VDC, max. with power on
Input Ranges
Bipolar Input Ranges -10V to +10V
Thermocouple Support Thermocouple Inputs J-type thermocouple
K-type thermocouple
T-type thermocouple
E-type thermocouple
R-type thermocouple
S-type thermocouple
Gains 1
10
100
200
500
Gain Range Details Gain is the same for each 16 channels. Gains are additive, so setting the gain switches on for gain=100 and gain=200 provides a gain of 300.
Analog Output Channels
Number of Analog Output (D/A) Channels 2
Unipolar Output Ranges 0 to +10V
Current Limit ±5mA
Output Impedance 100mΩ
Analog Output Features CJC channel outputs 24mV/°C, and CJC Zero Crossing is 0mV at 0°C.
Digital I/O Lines
Number of I/O Lines 4
Configuration 4 inputs
Inputs Input Voltage - High (Vih, DC) 2V....7V
Input Voltage - Low (Vil) -0.5V....0.8V
Digital Input Features 4 input bits are used to control scanning, allowing you to select the CYEXP 16 channel (0 through 15) to be read by the A/D board. Logic chip: 74LS14.
Software
Software Included Free with Product Diagnostic software
Setup_utility software
Software Included - Features Calibration.
Software Compatibility Labtech NOTEBOOK®
Universal Driver Library
Labtech NOTEBOOKpro®
LabVIEW® (with optional drivers)
Agilent VEE® (with optional drivers)
Cables and Connectors
Connector #1 Quantity 2
Type DB-37 (37-pin)
Gender Male (pin)
Connector #2 Type Screw terminals
Connector & Cabling Details The CYEXP 32 requires +5V power, which can usually be supplied from your A/D board (this method typically supports up to 5 CYEXP panels). +5V power can also be supplied via an on-board standard 4-pin male Molex connector. Our CBL MOL10 is a 10-foot M-F cable designed to bring +5V power directly from one of your PC's power supply Molex connectors to the CYEXP 16 or CYEXP 32.
Power
Power Consumption (typical) 120mA typ, 155mA max @ +5V
+5V 120mA
Indicators & Controls
Other Control Features Open thermocouple detect (OTD) for a channel is an option enabled by closing the associated 'V' pad with a solder bridge. OTD applies a full scale negative voltage to the high side of the thermocouple signal. If a thermocouple opens, the OTD voltage drives the signal on that channel to full minus. Most software is written such that an alarm will be set off for an open thermocouple when a temperature reading falls to full scale minus. The CYEXP 32 will accurately measure thermocouples without the 'V' pad closed, but you will lose the OTD protection.
Environmental Specifications
Operating Temperature 32°F....140°F (0°C....60°C)
Storage Temperature -40°F....212°F (-40°C....100°C)
Relative Humidity, noncondensing 0%....90%
Dimensions
Width 16" (406.5mm)
Height 0.74" (18.74mm)
Depth 4" (101.65mm)
Weight
Weight 0.86lbs (390.09g )
Shipping Weight 2.1lbs (952.54g )
Less Detail Less Detail
 
Ordering - Includes Options Indicated Below
CYEXP 32
32-Channel Analog Input Multiplexing Panel (32 inputs to 2 outputs)
$425.00
CYEXP 32L-5PK
32-Channel Analog Input Multiplexing Panel (32 inputs to 2 outputs) with Optional Removable Terminal Strips, Qty 5
$2,725.00

Terminal Panel Options
None  
CYSTA ENC
Rack / Bench Enclosure for STA, CYERB, CYEXP, and CYSSR Terminal Panels
$145.00
Catalog # Shipping Price (with options) Qty  
CYEXP 32 Call for Availability
Customers Were Also Interested In These
CYEXP 16 $325.00
16-Channel Multiplexing Panel - Scans 16 Differential Signals to One Output Channel
C5B 31-02 $175.00
5B Signal Conditioning Module - Isolated Voltage Input, ±5V Input, ±5V Output
C5B 31-03 $175.00
5B Signal Conditioning Module - Isolated Voltage Input, ±10V Input, ±5V Output
Did you find this page useful?