| System Bus |
USB 2.0 |
| Bus Information |
Bus Standards Compliance |
USB 1.1 USB 2.0 |
| Mounting Configuration |
Desktop / benchtop External module DIN-rail mount |
| Isolation |
Isolation Details |
- Dielectric Isolation (between relay open contact): 300VAC, 50/60Hz (1 min.)
- Dielectric Isolation (between PCB output lines): 500VAC, 50/60Hz (1 min.)
|
|
| Number of I/O Lines |
8 |
| Primary Digital I/O |
Configuration |
8 mechanical relays (outputs) |
Input/Output Selection |
Fixed | Signal Connector |
24 screw terminals | Inputs |
Isolation Type |
Mechanical (relays, etc.) | Outputs |
Relay Configuration |
SPDT (Form C: single pole, double throw) | Relay Contact Rating, max. |
6A | Relay Contact Rating |
6A @ 240VAC or 28VDC resistive | Resistance, Closed/On, max. |
100mΩ | Output Resistance Details |
- Dielectric isolation between relay open contacts: 300VAC, 50/60Hz (1 minute)
- Dielectric isolation between PCB output lines: 500VAC, 50/60Hz (1 minute)
| Power-On State |
User defined | Digital Output Features |
- Power On State (S2 = pull-up): Energized. NO in contact with Common
- Power On State (S2 = pull-down): Not energized. NC in contact with Common
- Pull-Up/Pull-Down: User-configurable per bank via switch S2 for pull-down (default) or pull-up. Switch settings can be read back via software. Pull-down will put the relays in non-energized mode on power uo. Pull-up will put the relays in energized mode on power up.
| |
| Software Included Free with Product |
Diagnostic software Drivers with source Setup_utility software calibration software |
| Operating System Compatibility |
Windows XP Windows 2000 Windows 98SE |
|
| Connector #1 |
Quantity |
24 |
Type |
Screw terminals | Location |
On module | | Connector #2 |
Quantity |
2 |
Type |
USB Type A (4-pin, rectangular) | | Connector #3 |
Quantity |
1 |
Type |
USB Type B (4-pin, square) | |
| Construction Material |
Metal Plastic |
|
| Power Supply Notes |
External 9VDC power supply included |
|
| Other Control Features |
- Switch 1 sets logic polarity by banks.
- Switch 2 sets pull-up/pull down by banks. Pull-up puts the relays in energized mode on power-up. Pull-down puts the relays in non-energized mode on power up. Pull-down is the default setting of Switch 2.
|
|
| Operating Temperature |
32°F....158°F
(0°C....70°C)
|
| Storage Temperature |
-40°F....212°F
(-40°C....100°C)
|
| Relative Humidity, noncondensing |
0%....95% |
| Other Environmental Specifications |
- Vibration: 10 to 55Hz (amplitude 1.5mm)
- Shock: 10g for 11ms max.
|
|
| Card Length |
8"
(203.2mm)
|
| Card Height |
4.76"
(121mm)
|
| Card Thickness |
0.8"
(20.3mm)
|
| Width |
5.07"
(128.7mm)
|
| Height |
1.66"
(42.25mm)
|
| Depth |
8.35"
(212.1mm)
|
| Dimension Details |
Card dimensions do not include relays. |
|
| Weight |
1.58lbs
(716.67g
)
|