| Mounting Configuration |
Rack-mount (EIA RS-310C Standard 19") Desktop / benchtop |
| Height, Rack Units |
2U (3.5") |
| Construction - Chassis Material |
Steel |
| Mounting Flanges |
Removable rack-mounting flanges included |
| Color |
Black |
|
| Front Panel Controls |
Other Controls/Features |
LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, and Overload indicators |
| Rear Panel Controls |
Other Controls/Features |
Audible alarm when on battery, distinctive low battery audible alarm, configurable alarm delays |
|
| Power Supply Input Connector |
Integral 8-ft AC power cord with NEMA L5-30P plug |
| Power Supply Output Connector |
6 AC outlets on rear panel (NEMA 5-15R) 2 AC outlets on rear panel (NEMA 5-20R) |
|
| Power Cord Included |
Integral 8-ft power cord |
| Cabling Details |
- serial cable included
- USB cable included
|
|
| Nominal Output Power |
2.7kW |
| Nominal Output Power, VA |
3000VA |
| Nominal Output Voltage |
120VAC |
| Power Supply Input Type |
AC |
| Input Voltage Range(s) |
82...144VAC |
| Input Frequency |
50/60Hz, ±3Hz |
|
| Surge Suppression Response Time |
0ns |
| Remote Monitoring Port Type |
RS-232 (9-pin serial) USB |
| Power Protection Special Features |
- Audible Alarms
- Automatic self-test
- Boost and Trim Automatic Voltage Regulation
- Building wiring fault indicator
- Cold-start capable
- Hot-swappable batteries
- Intelligent Battery Management
- Line-interactive
- Load Meter
- Network-grade line conditioning
- Overload Indicator
- Power conditioning
- Replace Batt Indicator
- Resettable circuit breakers
- Serial Connectivity
- Sine-wave output
- Software
- Status Indicator LED's
- Surge Protection
- Temperature Compensated Battery Charging
- USB Connectivity
- User Replaceable batteries
- Wide input voltage range
|
| Hold-Up Times |
Hold-Up Time at Full Load |
180s |
Hold-Up Time at Half Load |
678s | Details |
3 min at full load, 11.3 min at half load | |
| Operating Temperature |
32°F....104°F
(0°C....40°C)
|
| Storage Temperature |
5°F....113°F
(-15°C....45°C)
|
| Relative Humidity, noncondensing |
0%....95% |
| Altitude, Max. |
1.89mi
(3.05km)
|
|
| Safety/Approvals |
Meets UL standards Meets CSA standards Meets FCC Part 15 - Class A EMI specs Meets UL 1449 standards Meets UL 1778 standards |
|
| Width |
19"
(482.6mm)
|
| Width, Rack-Mount |
EIA RS-310C standard 19 inches at flanges |
| Width (without removable flanges) |
55.77ft
(17m)
|
| Height |
3.5"
(88.9mm)
|
| Height, Rack Units |
2U (3.5") |
| Depth |
2.17ft
(660.4mm)
|
| Shipping Width |
2.04ft
(622.3mm)
|
| Shipping Height |
10"
(254mm)
|
|
| Weight |
96.1lbs
(43.59kg
)
|
| Shipping Weight |
125lbs
(56.7kg
)
|